PENGARUH VARIASI DEBIT UDARA MASUK TERHADAP KAPASITAS AIR YANG DIHASILKAN OLEH ATMOSPHERIC WATER GENERATOR

Imam Safi'i, Widya Aryadi

Abstract


The water extracter from the air is still using the principle of external flow so it is considered cooling efficiency is still not good. In this research using internal air flow by using copper pipe with 2 type of design that is design A and B. This process of heat absorption does not occur suddenly, it takes time to arrive at equilibrium point, therefore the air discharge has affect the cooling process. The results showed that the air discharge affect the capacity of condensate water. Design A produces a maximum water capacity of 145 ml in one hour at 25 lpm, while design B generates maximum condensate water of 178 ml in one hour at 15 lpm.


Keywords


Atmospheric Water Generator, the influence of air volume.

References


Agra, S. W. 1989. Perpindahan Panas dengan Perubahan Fasa II Penguapan dan Kondensasi. Universitas Gadjah Mada. Yogyakarta.

Liu, S., W. Hei, D. Hu, S. Lv, D. Chen, X. Wu, F. Xu, S. Li. 2017. Experimental Analysis of a Portable Atmospheric Water Generator by Thermoelectric Cooling Method. International Journal of Science & Engineering Research, 142 (96):1609-1614.

Puspitasari, D. E. 2009. Dampak Pencemaran Lingkungan Air Terhadap Kesehatan Lingkungan dalam Prespektif Hukum Lingkungan (Studi Kasus Sungai Code di Kelurahan Wirogunan Kecamatan Mergangsan dan Kelurahan Prawirodirjan Kecamatan Gondomanan Yogyakarta). Mimbar Hukum, 21(1): 23-34.

Sugiono. 2009. Metode Penelitian Kuantitatif Kualitatif dan R&D. Cetakan ke 8. Bandung: Alfabeta


Full Text: PDF

DOI: 10.15294/sainteknol.v16i1.15135

Refbacks

  • There are currently no refbacks.