Experiment of Pullout Expansion Anchor in Installation Cast in Place and Post Installed with Concrete Breakout Failure
(1) Universitas Negeri Semarang
(2) Universitas Negeri Semarang
Abstract
Abstract: The use of anchors in construction is gaining popularity to connect steel and concrete constructions, and to transmit tensile loads acting onto the concrete. This research aims to find out the difference in the strength of anchor based on two methods of installations that are cast in place compared to post installed with the influence of effective depth, diameter of anchor and quality of concrete, and failure of concrete breakout. Expansion anchor used in this study is "Sanko" M12x100 and ready-mix concrete PT Bonindo Ungaran, fc 25 MPa with 6 pieces of test specimens of 300x300x150 mm. Each specimen has 4 anchors with a distance between the anchors of 100 cm, the distance between the anchors to the edge of the concrete 100 mm, and the depth of installation (hef) of 60 mm. The result of the study is the predicted value of the anchor pullout capacity with the failure of concrete breakout due to the theoretical pullout, namely 42,223 N, anchor pullout test results with cast in place method of 40,574 N and post installed method by 37,494 N. Tensile strength tests (material) of anchor (fy) 338 MPa, for flat concrete compressive strength strength of (f’c) 25,698 MPa. The results of the cast in place pullout test are larger and better than post installed (40574 N>37494 N). Failure that occurred in cast in place method is a failure of concrete breakout and post installed method has occurred slip. Failures that occur are relevant to the theory.
Keywords
Full Text:
PDFReferences
ACI. 2011. Building Code Requirements for Structural Concerete (318-11) An ACI Standard and Commentary. ACI 318-11. First Printing. Farmington Hills U.S.A: Reported by ACI Committee 318.
Badan Standarisasi Nasional. 2019. Standar Nasional Indonesia: Persyaratan Beton Struktural Untuk Gedung dan Penjelasan. SNI 2847-2019. Jakarta.
Bokor, Boglarka, Akanshu Sharma, dan Jan Hofmann. 2019. Experimental Investigations on Concrete Cone Failure of Rectangular and Nonrectangular Anchor Groups. Engineering Structures 188: 202-2017.
Delhomme, Fabien dan Michael Brun. 2018. Pullout Simulation Of Post Installed Chemically Bonded Anchors In UHPFRC. MATEC Web of Conferences 199, ICCRRR 2018. Cape Town, South Africa.
Dewobroto, Wirayanto. 2015. Struktur Baja (Perilaku, Analisis dan Desain – AISC 2010). Edisi Pertama. Cetakan Pertama. Banten: Lumina Press.
Eligehausen, R. et. al. 2006. Anchorage in Concrete Construction. First Edition. Berlin: Ernst & Sohn GmbH & Co. KG. Published.
Langi, William, Ellen J. Kumaat, dan Hieryco Manalip. 2018. Tegangan Lekat antara Baja dan Beton dengan Mutu Beton 40-70 MPa. Jurnal Sipil Statik 11 (6): 995-1002.
Nilforoush, Rasoul, Martin Nilsson, dan Lennart Elfgren. 2017. Experimental Evaluation Of Tensile Behaviour Of Single Cast-In-Place Anchor Bolts In Plain And Steel Fibre-Reinforced Normal- And High-Strength Concrete. Engineering Structure 147: 195-206.
Prasetyo, Imam, dan Henry Apriyatno. 2019. Studi Literatur Kapasitas Defleksi dan Lentur dan Defleksi Balok Beton Bertulang dengan Menggunakan Tulangan Spiral. Civil Engineering and Environmental Symposium 2019. Semarang.
Rao G. Appa dan B. Sundeep. 2015. Strength of Bonded Anchors in Concrete in Direct Tension. Digital Library of University Moratuwa. http://dl.lib.mrt.ac.lk/handle/123/9517. 24 Oktober 2019 (07:30).
Strba, Michal and Marcela Karmazinova. 2015. Experimental Verification of Load-Carrying Capcity in Case of Steel Post-Installed Expansion Anchors Subjected to a Tension Loading. Fluids, Heat and Mass Transfer, Mechanical and Civil Engineering. ISBN: 978-1-61804-358-0.
Refbacks
- There are currently no refbacks.