Design and Characterization of Low-Cost Sensors for Air Quality Monitoring System
Abstract
In this study, low-cost sensors for air quality monitoring system have been characterized and designed. These sensors are applied in a monitoring system and installed at Sriwijaya University, which is vulnerable to the impacts of forest fires in the surrounding area. This monitoring system will provide information especially for the university community to determine the level of air quality on campus. In this research the researchers focussed on the characterization and design of system sensor that aimed to get the best configuration of low-cost sensors namely MQ-7, Sharp GP2Y1010AU0F and own-designed smoke sensor to have high reliability and effectiveness to be applied to monitoring systems. The test results showed that the sensors have good response and sensitivity. Therefore, it can be applied to the monitoring system to provide information about the level of particle concentration, carbon monoxide and smoke which meet the needs of low-cost monitoring systems.
Keywords
Full Text:
PDFReferences
BAPEDAL.(1998).Pedoman teknis perhitungan dan pelaporan serta informasi indeks standard pencemar udara.
Brook, R.D. et al. (2010). Particulate Matter Air Pollution and Cardiovascular Disease: An Update to the Scientific Statement From the American Heart Association. Circulation: journal of American Heart Association, 121; 2331-2378
Glauber, A.J., & Gunawan, I.(2016). The Cost of Fire: An Economic Analysis of Indonesia's 2015 Fire Crisis.2015.The World Bank
Goudarzi, G., Geravandi, S., Naimabadi, A., Mohammadi, M.J., Neisi, A.K., Sadattaghavirad, S., Filban, F. (2014) Cardiovascular deaths related to Carbon monoxide Exposure in Ahvaz, Iran.Iranian Journal of Health, Safety &Environment, Vol.1, No.3, pp.126-131
Guo, S., Hu, M., Zamora, M. L., Peng, J., Shang, D., Zheng, J., Du, Z., Wu, Z., Shao, M., and Zeng, L. (2014). Elucidating Severe Urban Haze Formation in China. Proc. Natl. Acad. Sci., 111(49):17373–17378
Hanwei Electronics Co., Ltd. Technical Data Mq-7 Gas Sensor.www.sparkfun.com/datasheets/Sensors/Biometric/MQ-7.pdf (Accessed 21 May 2018)
Kumar, P., Morawska, L., Martani, C., Biskos, G., Neophytou, M., Di Sabatino, S., Bell, M., Norford, L., Britter, R., 2015. The rise of low cost sensing for managing air pollution in cities. Environment International 75, 199–205 Online link: http://dx.doi.org/10.1016/j.envint.2014.11.019
Pribadi, A., & Kurata, G. (2017). Greenhouse gas and air pollutant emissions from land and forest fire in Indonesia during 2015 based satellite data. IOP Conference Series: Earth and Environmental Science ; 54(2017)012060.
Sharp Corp. (2006). GP2Y1010AU0F Compact Optical Dust Sensor Datasheet : Sheet No.: E4-A01501EN.
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., Biswas, P. (2015). Laboratory Evaluation and Calibration of Three Low-Cost Particle Sensors for Particulate Matter Measurement. Aerosol Science and Technology, ISSN: 0278-6826. pp. 1063 - 1076.
Refbacks
- There are currently no refbacks.